What is the function of the weight reduction rate of a balancing machine?
Article category:FAQ
Post date:2024-10-21 15:22:16
What is the role of the weight reduction rate of the balancing machine in rotor dynamic balance correction?
During dynamic balance detection, due to the inherent unbalance of the measured rotor and the fact that the measured test weight is a composite quantity, when using a Shenman dynamic balancing machine for dynamic balance correction, unless a suitable standard rotor is found at this time.
The most commonly used method is to first measure the initial test quantity and angle. After measuring the initial test quantity and angle, vector subtraction can be used to calculate the added test mass. Another method is to first measure the unbalance of the rotor, then reduce the initial unbalance of the rotor during the measurement, and then use a dynamic balancing machine to measure the balance value.
What is the role of the weight reduction rate of the balancing machine in rotor dynamic balance correction?
1. Is the weight and position of the counterweight placed during operation accurate.
2. The gap between the drive shaft cross shaft and the telescopic sliding button.
3. Is the calibration of the balancing machine accurate.
Generally, after a single calibration of a hard support balancing machine, there is no need for further calibration when measuring different workpieces, while soft supports require repeated calibration. At present, Huake Zhichuang Shenman fully automatic balancing machines do not require manual calculation and measurement of unbalance angles.
During dynamic balance detection, due to the inherent unbalance of the measured rotor and the fact that the measured test weight is a composite quantity, when using a Shenman dynamic balancing machine for dynamic balance correction, unless a suitable standard rotor is found at this time.
The most commonly used method is to first measure the initial test quantity and angle. After measuring the initial test quantity and angle, vector subtraction can be used to calculate the added test mass. Another method is to first measure the unbalance of the rotor, then reduce the initial unbalance of the rotor during the measurement, and then use a dynamic balancing machine to measure the balance value.
What is the role of the weight reduction rate of the balancing machine in rotor dynamic balance correction?
1. Is the weight and position of the counterweight placed during operation accurate.
2. The gap between the drive shaft cross shaft and the telescopic sliding button.
3. Is the calibration of the balancing machine accurate.
Generally, after a single calibration of a hard support balancing machine, there is no need for further calibration when measuring different workpieces, while soft supports require repeated calibration. At present, Huake Zhichuang Shenman fully automatic balancing machines do not require manual calculation and measurement of unbalance angles.